Overview
Equipment Details | Average Installation Time | On This Page | ||
Make: [VARIES] TEST
F2 Reader Installation Guides
| TODO |
Known Models
STGT79WN
This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.
Required Hardware
Card Reader
One of the following readers.
Part ID | Description | Image |
---|---|---|
C-3001 | LC WiFi Reader Front/Vertical Mount | |
C-3002 | LC WiFi Reader Top/Horizontal Mount | |
C-5401 | F2 FasCard Reader Front Mount | |
C-5402 | F2 FasCard Reader High Front/Top Mount | |
C-5403 | FLEX Reader Front/Vertical Mount | |
C-5404 | FLEX Reader Top/Horizontal Mount |
Recommended Tools and Supplies (Not Included)
See 3593 F2 Reader Install Guide for more information.
Installation
- Page not found for multiexcerpt macro.
Install Mounting Hardware
Coin and Card
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
Card Only - Coin Ready
Remove existing coin box.
- Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
Bend the side tabs of the C-0940 Vault Cover outward and install into the coin vault. The tabs should snap into place securing the bracket.
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
Card Only - Card Ready
Place the C-6700-TEMP Drill Template on the desired mounting location.
Verify included harnesses will reach desired location without encountering interference from internal machine components.
Refer to FasCard Mounting Guide for further instructions.
Connect Power
- Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
- Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
- Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.
Connect Coin Sense Harness
Coin Drop: MDC Control
- Disconnect the Coin Drop from the Machine Control Assembly.
- Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.
Connect Machine Interface Harness
Pulse
- Connect the C-5300-NC Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.
Serial
- Connect the C-0110-TOP Machine Start Harness to the H5 connector on the Machine Control Assembly.
Connect and Mount Reader
Item No. | Component | Notes |
1 | Power Connection Port | Utilizes the same power harnesses as the first generation FasCard reader. |
2 | Pulse Connection Port | Connection point for pulse machine start harnesses. |
3 | Coin 1 Connection Port | This is the connection point for the harness input associated with Coin 1. |
4 | Coin 2 Connection Port | This is the connection point for the harness input associated with Coin 2. |
5 | Serial Connection Port | This is the connection point for serial machine start harnesses. |
- Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
- Connect the free end of the Machine Start Harness:
- If following steps for a serial Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
- If following steps for a pulse Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
- Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
- Connect the free end of the C-5500 Power Extension Harness to port 4 (C-5500 Power Harness Connection Port) as shown in the image above.
- Secure the FasCard reader to base as described in the FasCard Mounting Guide.
Machine Configuration
- Power off the machine.
- Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.
- Power on the machine.
FasCard Admin Site Configuration
Use the following settings depending on the Machine Start Harness used.
Pulse (C-XXXX)
- Equipment Type: XXXX
- Pulse Length: XX
Serial (C-XXXX)
- Equipment Type: XXXX