Overview

Equipment Details


Average Installation Time


On This Page

Make: Maytag


TODO


Associated Models

MHN33PD000
MHN33PDCGW
MHN33PDCW2
MHN33PDCWW
MHN33PDCXW
MHN33PR000
MHN33PR001
MHN33PRCWW

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 3114 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Card Models

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Remove the (4) security torx retaining screws on the front of the machine.

  2. Remove the soap tray by pulling it out and pressing on the retaining tab in the rear of the tray.

  3. Locate and remove the (2) security torx screws inside the soap tray opening.
  4. Remove the final (2) torx screws to open the top cover.
  5. Locate a spot on top of the machine to mount the reader. Verify included harnesses will reach desired location without encountering interference from internal machine components. Mark the location using C-6700-TEMP Drill Template.
  6. Refer to F2 Reader Mounting Guide for instructions on drilling mounting holes and mounting the reader.

Card Only - Coin Models

P/N: C-0303
Topload Mounting Bolt
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1
P/N: C-6911
F2 Metercase Bracket
Whirlpool - White
Qty: 1

  1. Remove the mounting bolt securing the coin drop to the metercase. Then remove the coin drop and coin box.

  2. Attach the C-5414 Reader Mounting Bracket to the C-6911 Metercase Bracket using the C-5702 Chase Nipple and C-5703 Nut.
  3. Run reader harnesses through the metercase and the hole on the C-6911 Metercase Bracket.

  4. Install C-6911 Metercase Bracket into the metercase and secure using C-0303 Mounting Bolt.

Connect Power

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 2
P/N: C-5336
Power Adapter Harness
Dexter Stack
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Locate the incoming power cables in the rear of the machine. This should include a white, black and green wire.

  2. Use the C-5101 Spade Taps to tap the black (L1) and white (Neutral) wires.
  3. Attach the spade ends of the C-5336 Power Adapter Harness to the taps. Blue to black, and Brown to White.
  4. Attach the Green ground wire from the C-5336 Power Adapter Harness to a nearby chassis ground screw.
  5. Connect the 3-pin connector from the C-5336 Power Adapter Harness to the 3-pin connector on the C-5602R1 Power Converter.
  6. Connect the 4-pin connector from the C-5602R1 Power Converter to the 4-pin connector on the C-5500 Power Extension Harness.
  7. Mount the C-5602R1 Power Converter in the machine by using zip ties to secure it to the machine's wire harness.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-6362
Coin Sense Harness
MLG
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6362 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse

P/N: C-0128-MLV
Machine Start Harness
Maytag
Qty: 1

  1. Connect the C-0128-MLV Machine Start Harness to the Debit connector on the Machine Control Assembly.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the C-0128-MLV Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
  3. Connect the free end of the C-6362 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Harness to port 1.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-0128-MLV)

  1. Equipment Type: SingleVend
  2. Pulse Length: 24

  • No labels