Overview

Equipment Details

Make: [VARIES]

On This Page

Associated Models

DOOR

Recommended Tools and Supplies

Installation

Install Mounting Hardware

Kit: M02B-004 (Surface Mount - Door Strike)

Part #: C-0141

Desc 1: Screw

Desc 2: 8-32 x 1-1/2" - Cap

   Qty: 2

Part #: C-5027

Desc 1: Label

Desc 2: Credit Card Logo

   Qty: 1

Part #: C-5700

Desc 1: Mounting Bracket

Desc 2: Surface Mount

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.
  2. Mark hole "D" for the pilot hole to run the harnesses to the reader. Mark "C" and "E" holes to provide mounting points for the reader bracket.
  3. Use a 1-1/8" hole saw to drill a hole at position "D".
  4. Place and align C-5700 F1 Mounting Bracket so that the center hole aligns with hole "D" and the two holes immediately to the left and right align with the holes marked for "C" and "E"
  5. Using material appropriate fasteners (Not Provided.), secure the C-5700 F1 Mounting Bracket to the surface using points "C" and "E"
  6. Optional: If accepting credit cards, apply the C-5027 Label on or near the F1 card reader for applicable credit cards.

Connect Power

Kit: P140-009 (120v Wall Power)

Part #: C-5200-72

Desc 1: 72" Power Adapter Harness

Desc 2: 120V Line Cord

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Connect the C-5200-72 Powerline Adapter Harness to an 120v electrical outlet.

  2. Connect the white, 3-pin connector from the C-5200-72 Powerline Adapter Harness to the matching end on the C-5602R1 Power Converter.
  3. Connect the 4-pin connector from the C-5500 Power Extension Harness to the matching end on the C-5602R1 Power Converter.

Connect Machine Interface Harness

Kit: T150-040 (Pulse - Circuit Interruption)

Part #: C-5256

Desc 1: Machine Start Harns (pulse)

Desc 2: 20" - Male taps, Rq. Female

   Qty: 1

  1. Connect the one of the ends of the C-5256 Machine Start Harness to the positive terminal from the door strike power source. Connect the other spade connector to the positive terminal on the door strike.
    1. Note: Depending on the door strike installed, spade terminals may not be available or may be too far apart for the harness to reach. In this case, cut the ends of the C-5256 Machine Start Harness and then cut and splice into the positive lead wire (In any pairing.). 
  2. The negative lead from the door strike power source should remain connected to the negative terminal on the door strike.
  3. Note: If the door strike requires a normally closed circuit instead of a normally open one, move the wire in the 6th position to the 4th position on the C-5256 Machine Start Harness.

Connect and Mount Reader

  1. Feed remaining harness ends through the mounting hole.
  2. Connect the free end of the C-5256 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-5500 Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

CCI Software Configuration

Machine Control: *NO NAME*
 Pulse: SingleVend (Relay) / ANY
 Serial: *NOT SUPPORTED*